Fire Safety Compliance

For Care Homes, HMOs & Local Authority Housing.

We check the things that actually get people out alive: fire extinguishers, fire doors, and the auditable digital paperwork that proves it.

If something’s not compliant, we fix it.

Fire Safety

Why It Matters.

Independent inspection data from the Fire Door Inspection Scheme, covering more than 100,000 UK fire doors, found that 75% failed to meet the required standard, with local authority housing, housing associations, and healthcare buildings among the worst-performing building types.

Most failures are small, avoidable things; a missing intumescent seal, an oversized gap, a self-closer that no longer latches… but under the law, a fire door with any one of those faults is a fire door that has failed.

Who This Is Important To.

Renovations
Care Homes

Higher-risk, higher-vulnerability settings where residents may not be able to self-evacuate. Fire risk assessments and equipment checks here are held to a higher standard under the Regulatory Reform (Fire Safety) Order 2005, reflecting the additional risk of sleeping accommodation.

HMO Conversions
HMOs

The Management of Houses in Multiple Occupation (England) Regulations 2006 STATE landlords and managing agents must maintain fire-fighting equipment and alarms in working order across shared entrances, stairs, and corridors, alongside their obligations as the “responsible person” under the Fire Safety Order.

Housing Associations
Housing Associations

Local Housing & Housing Association Stock. Every block, every building, every fire door: checked, logged, and evidenced, so your compliance records hold up to scrutiny.

The Law Behind It

Fire safety compliance in England isn't optional, and it isn't static, it's been reshaped significantly since Grenfell. We don't just check boxes against this. We can explain exactly which requirement applies to your building, and evidence it. Here's what actually governs the work:
1.
Regulatory Reform (Fire Safety) Order 2005

Whoever has control of a building (the “Responsible Person”) must ensure fire doors, fire-fighting equipment, and escape routes are kept in efficient working order and good repair (Article 17).

2.
Fire Safety Act 2021

Confirmed that fire risk assessments in multi-occupied residential buildings must also cover external walls and flat entrance doors.

3.
Fire Safety (England) Regulations 2022

Sets specific inspection frequencies for fire doors, scaled by building height.

4.
Building Safety Act 2022, Section 156

Since October 2023, every Responsible Person must record their fire risk assessment in full, regardless of the size of their organisation.

5.
Management of Houses in Multiple Occupation (England) Regulations 2006

Sets out the specific fire safety maintenance duties that apply inside HMOs.

If Something is NOT compliant.

Finding a problem is only half the job. Where extinguishers, fire doors, or signage fall short, we can put together a remedial package to bring the building back into compliance.

This can include the supply and installation of the right equipment, fire door repair or replacement, signage, and a scheduled maintenance plan so it doesn’t lapse again.

Fire Extinguisher

What We Do.

Prosure Property
Assessment

We visit site and carry out a full check of fire extinguishers and fire doors against current legal requirements.

Prosure Property
Report & Findings

You receive a clear written report: what’s compliant, what isn’t, and why it matters.

Prosure Property
Remedial Works

Where action is needed, we carry it out. Repair, replacement, or new equipment, on an agreed timeline.

Prosure Property
Sign-Off & Records

You’re left with evidenced, dated compliance records you can produce on demand.